Main applications :
Pressure sensing on water heaters, boilers, spas and swimming pool heaters and filters, sprinklers circuits, electrical appliances. Its high electrical rating allows its use on pumps, motors, electrical heaters.
The two independent set points allow use in control plus alarm, control with differential adjustment, or high and low pressure alarm. They are intended to be incorporated by OEM.
Main Features : Membrane: Two Silicone membranes, dia 17.5 mm.
Fluid: Water or air
Fitting: PA66, 1/2"NPT, 1/2" BSPT or 1/2" BSPP
Pressure: Positive
Contacts: Two SPDT, snap action.
Electrical rating: 2 x 22 (8)A 250VAC, (2HP)
Action: Momentary.
Set point calibration: Field adjustable with knob
Standard adjustment ranges (mbar): 300 to 600; 400 to 1200; 900 to 3000; 1400 to 5000;1500 to 9000. These devices can also be factory calibrated upon customer request.
Electrical connection: 6.35 x 0.8mm quick connect terminals Maximum operating pressure: 12 bar (1.2 Mpa, 174 PSI) Bursting pressure: > 50 bar (5 Mpa, 725 PSI)
Ambient temperature limits:
Air: -10 to 85°C (14 to 185°F)
Water : 0 to 85°C (32 to 185°F)