Main applications
Electronic printed circuits. Detection of low positive, negative or differential pressure. Measurement of liquid levels, air flow, filters efficiency. Very small differential, about 0.2 kPa (2 mbar, 0.03 PSI)
Membranes: Silicone, dia 22mm.
Fluid: Air only
Fitting: Two plastic spouts dia 4mm for soft PVC tube 3 × 6mm (⅛”)
Pressure: Differential
Housing: PA66
Contact: Single pole normally open, slow make and break.
Electrical rating:
- Silver contact: max 1A 250VAC resistive
- Gold plated contact: max 100 mA, 24VDC
Action: Momentary, close by pressure rise on positive pressure inlet
Set point calibration: Factory calibrated and sealed
Set point calibration limits: From -/+1 to -/+60 kPa (-/+ 10 to -/+ 600 mbar, -/+0.15 to -/+9 PSI)
Differential: Less than 0.5 kPa (5 mbar, 0.07 PSI)
Electrical connection: printed circuit terminal, dia. 1mm, 12.5mm distance
Maximum operating pressure: -/+ 90kPa(-/+ 900mbar, -/+ 13PSI)
Bursting pressure: > 4bar (0.4Mpa, 60PSI)
Ambient temperature limits: Air: -10 ~ 85°C (14 to 185°F)
Note: 10 kPa= 100 millibars = 1.45 PSI= 40 inches of water = 1016mm of water.