Housing dimensions: 79.5 × 51 × 28.5mm (6.3 quick connect terminals and manual reset button not included)
Bulb and capillary: Copper or stainless steel depending on temperature range, standard capillary length 1500mm. Capillary minimum bending radius 5mm
Temperature sensing element: Liquid filled bulb and capillary
Terminals: 3 tabs 6.35 × 0.8mm
Adjustment: Non-adjustable set point, factory sealed
Mounting: By 2 M4 screws, 28mm distance or by M10 × 1 bushing.
Rating: 16A (¼ HP) 250VAC, 16A 400V res
Contact: SPDT (snap action contact), manual reset.
Electrical life: >100,000 cycles at nominal rating
Accessories: M10 × 1 nut and manual reset cap are included
Options: Fixed setting can be replaced by screw driver with limited adjustment possibilities