- Air and Fluid heating solutions
- Renewable energy
- Industry
- Agriculture and Farming
- Petrochemistry
Applications
These temperature sensors have been designed to be mounted in holes dia. 20mm (With a lock nut and a gasket) or in M20x1.5 threads (With a gasket), originally intended for mounting cable glands on connection boxes or control boxes. They allow to easily install an ambient temperature sensor on these boxes. The ambient temperature measurement is then made outside, 15mm from the wall, and the system is fully waterproof.
Main features
Pt 100 3 wires RTD temperature sensor:
- Connection: 3 wires 0.5mm² (AWG24), FEP insulation + metallic braid + FEP. The 2 white wires are connected to one pole of the Pt100, the red wire to the other pole.
Negative temperature coefficient (NTC) thermistor temperature sensor:
- Connection: Black 2 wires 0.5mm² cable (AWG24), FEP + Silicone insulation. A black wire, a red wire. Each of these wires corresponds to a pole of the thermistor. Resistance variation curve: value 10 Kilo-ohms at 25°C, coefficient B 3380.
K thermocouple sensor:
- Connection: Green 2 wire 0.5mm² cable (AWG24), FEP + FEP insulation. Colour code according to IEC 584-3. The white wire is negative, the green wire is positive. (Colour code upon other standards on request).
J thermocouple sensor:
- Connection: Black 2 wire 0.5mm² cable (AWG24), FEP + FEP insulation. Colour code according to IEC 584-3. The white wire is negative, the black wire is positive. (Colour code upon other standards on request).