Housing dimensions: 43 × 35 × 29mm (without terminals
Bulb and capillary: Stainless steel, with 100mm long PVC sleeve on the capillary. Capillary minimum bending radius is 5mm. No capillary sleeve for temperature ranges above 400°C (750°F).
Temperature sensing element: Oil filled bulb and capillary.
Caution: Temperatur ranges above 400°C (750°F) are filled with sodium-potassium eutectic. In case of breakage of the bulb or capillary, this liquid may self-ignite at room temperature in the presence of water or moisture.
Terminals: 6.35 × 0.8 quick connect terminals, 90° bended. Straight terminals or terminals with M4 screws also available on request. (MOQ apply). Terminal positions and alignment allow the use of a connector with flat or bended terminals.
Adjustment: Dia. 6mm shaft with 4.6mm flat, length 11.5mm. Other lengths, screw driver adjustment or fixed setting available on request
Mounting: front bracket with 2 × M4 threads, 28mm distance.
Grounding: M4 thread on mounting bracket.
Contact:SPDT.
Electrical rating:
When the rated voltage is 250V~:
- Open on temperature rise contact (C-1): 20(3.3)A 250V~, 50-60Hz
- Close on temperature rise contact (C-2): 6A 250V~, 50 ~60Hz
When the rated voltage is 400V~:
- Open on temperature rise contact (C-1): 16(2.6)A 400V~, 50-60Hz
- Close on temperature rise contact (C-2): 2A 400V~, 50 ~60Hz
Electrical life: 100, 000 cycles
Max ambient temperature on body: 85°C (185°F).
Acceptable degree of pollution for use in 250V: 3
Acceptable degree of pollution for use in 400V: 2