Housing dimensions: 43 × 35 × 29mm (without terminals
Bulb and capillary: Stainless steel, with 150mm long PVC sleeve on the capillary. Capillary minimum bending radius is 5mm.No capillary sleeve for temperature ranges above 400°C (750°F)
Temperature sensing element: Oil filled bulb and capillary
Caution: Temperatur ranges above 400°C (750°F) are filled with sodium-potassium eutectic. In case of breakage of the bulb or capillary, this liquid may self-ignite at room temperature in the presence of water or moisture.
Terminals: 6.35 × 0.8 quick connect terminals, 90° bended. Straight terminals or terminals with M4 screws also available on request. (MOQ apply). Terminal positions and alignment allow the use of a connector with flat or bended terminals.
Adjustment: Dia. 6mm shaft with 4.6mm flat, length 11.5mm. Other lengths, screw driver adjustment or fixed setting available on request
Mounting: front bracket with 2 × M4 threads, 28mm distance.
Grounding: M4 thread on mounting bracket.
Contact:SPDT.
Electrical rating, resistive loads:
-Open on temperature rise contact (C-1)
20A 250V 50-60Hz: >50,000 cycles
16A 250V 50-60Hz: ≥100,000 cycles
16A 400V 50-60Hz: ≥50,000 cycles
Close on temperature rise contact (C-2): 6A 250V 50-60Hz: >100,000 cycles;2A 400V 50-60Hz: >100,000 cycles
Electrical rating, inductive loads: Open on temperature rise contact (C-1):
3A 250V 50-60Hz: >50,000 cycles; 2.6A 250V 50-60Hz: >100,000 cycles.
Max ambient temperature on body: 115°C (239°F