These thermostats were developed for use on the bodies of heaters, in conditions where condensation or drops of water are likely.
The thermostat body is covered with a flexible silicone cap, allowing eventual manual reset without risk of manual contact with live parts. In order to avoid tearing of the cap by handling, it is held in place by a stainless steel flange.
The cup of the thermostat is made of stainless steel to avoid the risk of galvanic corrosion between the body of the heater and thermostat, in a humid environment. They are designed to control the liquid temperature, and their use as a dry run safety is not recommended.
When used as a safety device, when they have trigged, it is mandatory to find and repair the failure of the heating circuit before to restart.
Protective cap: black silicon (1)
Electrical rating: 10A 250V (16A on request, contact us)
Action: Contact opens by temperature rise. Available in manual reset (3) or automatic reset by temperature drop.
Automatic reset models can be made in an alarm version, with close on temperature rise contact.
Open temperatures: 20 to 150°C according to specifications. The most common versions used in heaters are shown in the table below.
Connecting cable: FEP insulation, two conductors, AWG18, under heat shrink sleeve. (Other dimensions and insulation on request)
Cable length: 500mm standard, other length on request.
Cable end: fitted with crimped cable shoe
Mounting: Stainless steel flange (2), designed to receive two M3 screws, 24mm distance, for fixing on the installed heaters brackets Mounting on the body of tanks: it is recommended to use thermo-conductive grease between thermostat cup and tank.