- Air and Fluid heating solutions
- Renewable energy
- Industry
- Ventilation
- Professionnal kitchen
Housing dimensions: 43 × 35 × 29mm (without terminals)
Bulb and capillary: Sainless steel. Capillary minimum bending radius 5mm.
Temperature sensing element: Liquid metalloid filled
Terminals: 6.3 × 0.8 quick connect terminals. M4 screws also available on request.
Adjustment: Dia. 6mm shaft with 4.6mm flat, length 11.5mm. Other lengths, screw driver adjustment or fixed setting available on request.
Mounting: Front bracket with 2 × M4 threads, 28mm distance
Contact:SPDT.
Electrical rating:
When the rated voltage is 250V~:
- Open on temperature rise contact (C-1): 20(3.3)A 250V~, 50-60Hz
- Close on temperature rise contact (C-2): 6A 250V~, 50-60Hz
When the rated voltage is 400V~:
- Open on temperature rise contact (C-1): 16(2.6)A 400V~, 50-60Hz
- Close on temperature rise contact (C-2): 2A 400V~, 50-60Hz
Electrical life: 100, 000 cycles
Max ambient temperature on body: 85°C (185°F).
Acceptable degree of pollution for use in 250V: 3
Acceptable degree of pollution for use in 400V: 2