Home
  >  
Controls and Safety : Automatic Thermostat
  >  
Type Y08
Type Y08
Combination of adjustable set point thermostat and manual reset high limit, IP54 commercial housing, With immersion heater mounting bracket
Controls and Safety
Automatic Thermostat
Check PDF
Click to see more languages available in the datasheet
Product applicable fields
    The product does not currently have its own area
product presentation

Main applications:Control sub-assembly designed to be fitted directly on standard immersion heaters. Power up to 3500W, 230V, single phase.

Housing: IP54, 105 × 88 × 84.5mm, (Cap, accessories and cable gland not included), black PC-ABS, UL94V0. High impact and UV resistance. Product including an adjustable temperature control thermostat and a fixed setting high limit manual reset thermostat. Manual reset has access from outside, by removing a cap.

Electrical input: one M20 cable gland.

Temperature Adjustment: Inside, with °C printed knob. (°F printed knobs available in option)

Sensing elements: Liquid filled bulbs, dia. 6mm, with output on backside, for mounting inside immersion heater pockets

Adjustment ranges: 0-60°C (32-140°F); 30-90°C (85-195°F); 30-110°C (90-230°F)

Sensing element output lengths (C): 500mm (standard), other lengths from 150mm to 800mm available on request

Electrical connections:

      - Power supply (Neutral, Line, Ground), on 6mm² screw terminals.

      - Immersion heater: 3 wires, FEP 180°C insulated, 2.5mm², equipped with ring terminals, length 50mm on the immersion heater connection side, for direct connection on heating element M4 terminals. (Neutral wire is blue color)

      - Pilot light (Option): can be connected by a strap on power supply, or on control thermostat output, or on safety thermostat output. Mounting: by the backside extension, on the 50mm diameter hole, that can be used for immersion heaters with 1”1/2 thread or M45 thread, mounted by nut or by dia 56mm rotation ring

Control thermostat contact: Open on temperature rise contact (C-1) 16A (2.6) 250VAC - Electrical life >100,000 cycles.

Manual reset thermostat contact: Fail safe, open by temperature rise; 16A (2.6) 250V alt. Control thermostat and manual reset thermostat contacts are in serial on the Line supply of immersion heater.

Options:

      - Pilot light (230V)

      - Liftable adjustable high end adjustment on control thermostat.

      - Outside access to the control thermostat adjustment (By removing a 40mm dia. cap)

      - Thermal cut out for incorporation inside immersion heater pocket.