Combination of adjustable set point thermostat and manual reset high limit, IP54 commercial housing, capillary output, wall mounting
Controls and Safety
Automatic Thermostat
Check PDF
Click to see more languages available in the datasheet
Product applicable fields
  • Air and Fluid heating solutions
  • Renewable energy
  • Industry
  • Ventilation
  • Professionnal kitchen
  • Agriculture and Farming
product presentation

Main applications: Control sub assembly designed to be used directly on standard immersion heaters, power up to 3500W, 230V, single phase

Housing: IP54, 105 × 88 × 58.5mm, (Cap, accessories and cable gland not included), black PC-ABS, UL94V0. High impact and UV resistance. Product including an adjustable temperature control thermostat and a fixed setting high limit manual reset thermostat. Manual reset has access from outside, by removing a cap.

Electrical input: Two M20 cable glands.

Temperature Adjustment: Inside, with °C printed knob. (°F printed knobs available in option)

Sensing elements: Liquid filled bulbs, dia. 6mm, with output on side of housing, for distance measurement.

Adjustment ranges: 0-60°C (32-140°F); 30-90°C (85-195°F); 30-110°C (90-230°F) Capillary lengths (C): 900mm

Electrical connections: screw terminals Mounting: With 2 wall mounting tabs, for M4 screws, 62mm distance

Control thermostat contact: SPDT

      - Open on temperature rise contact (C-1) 16A (2.6) 250VAC

      - Close on temperature rise contact (C-2) 6A (0.6) 250VAC

      - Electrical life >100.000 cycles.

Manual reset thermostat contact: Fail safe, open by temperature rise; 16A (2.6) 250V alt.

Options:

      - Power supply “energized” pilot light (Neutral is mandatory, and thermostat contact is open on rise only, not SPDT) Other pilot light wirings are possible on request.

      - Liftable adjustable high end adjustment on control thermostat.

      - Outside access to the control thermostat adjustment (By removing a 40mm dia cap)