Controls and Safety : Automatic Thermostat
  >  
Type Y2W
Type Y2W
Thermostat with internal adjustment, IP65, with two pilot lights, for surface mounting on industrial jacket heaters, blanket heaters and silicone heaters
Controls and Safety
Automatic Thermostat
Check PDF
Click to see more languages available in the datasheet
Product applicable fields
    The product does not currently have its own area
product presentation

Applications:Developed for industrial applications in electric blankets, heating belts, jacket heaters, silicone heaters this thermostat is equipped with a flat sensitive part allowing to put it in contact with a surface, 4 holes allowing to mount it on this surface, and a direct passage between the connection terminal block and the back of the housing, for the passage of wires to the heating element.

Housing: IP65, 120 × 50 × 58.5 mm, fiberglass reinforced PA66, UL94V0. High impact and UV resistance, with transparent cover in polycarbonate

Electrical input: ISO M20 cable gland, Black PA66, IP67, for cables from 6 to 12 mm dia.

Electrical output: 2 dia.4 mm holes, located on the backside face, allow to introduce the heating element wires directly inside the housing. If IP65 ingress protection is requested on the backside, these 2 holes must be sealed around the wires with RTV silicone.

Temperature adjustment: By temperature printed dial.

Sensing element: Liquid filled bulb, located inside the brass cap.

Adjustment ranges: 30-90°C (85-195°F), 30-110°C (85-230°F).

Pilot lights: Allow to visualize the power supply and thermostat contact position.

Electrical connections: Inside, on 2.5mm² screw terminals connection block.

Mounting: By 4 holes for screws dia. 4mm, 40 × 110 mm distance.

Electrical rating: Open on temperature rise contact (C-1), 16A (2.6) 250VAC, >100.000 cycles.

Minimum Storage temperature: -35°C (-30°F)

Maximum ambient temperature: 110°C (230°F)