中文
English
Home
Applications
Products
Certification
About Us
Contact
Home
  >  
Components and Accessories : Other
  >  
Type BF
Type BF
Type BF
Flat PA66 connection blocks, T200°C
Components and Accessories
Other
Check PDF
Click to see more languages available in the datasheet
Product applicable fields
    The product does not currently have its own area
product presentation

Applications

In electrothermal connection blocks, the requirements are higher than in standard applications: high ambient temperature, frequent thermal cycles, proximity of the ends of the heating elements and their terminals, in a confined space making it difficult for the user to make the wiring.
These terminal blocks have been developed to meet these constraints. However, as they are not protected against accidental electrical contact, they are intended for internal wiring inside enclosures.

Main features, identical for all types

Body: Fiberglass-filled Polyamide 66, UL94V0, GWFI (Glow wire flammability index) 960°C, ambient temperature up to 200°C. Heat deflection temperature under 1.8 MPa load according to ISO 75: 226°C. Halogens free.

Terminals: M3 screw terminals, captive with the screw elastic toothed washer, resistant to loosening by vibrations or thermal cycles. These terminals can receive conductors equipped with fork or eyelet wire end terminals but this termination limits the clamping capacity to a single conductor. Cables equipped with cable shoes are limited to 1.5mm² maximum cross-section. The M3 screw can adapt a 4.8mm tab, and jumpers for the interconnection of the terminals are available (see the accessories page)
They are also available with one side equipped with solder terminals and the other with screw terminals. But when terminal blocks have solder terminals, this side can only receive one conductor from 1 to 2.5mm².

Voltage: 400V. The creepage distances between 2 terminals or between live and ground terminals are equal to or greater than 5mm, and clearances in air greater than 3mm (§8.4.2.2 and 8.4.2.3 of EN60947-7-1)

Wire gauge: Unless otherwise specified, each terminal equipped with screw and square washer accepts on each side one or two conductors from 1mm² to 2.5mm². (AWG 18 to AWG14).

Maximum rating per terminal: 24 A, corresponding to a self-heating of the terminal lower than 45°C, required by IEC60947-7§7.2.1.

Other models: similar PA66 terminal blocks for special immersion heater applications have also been developed:see catalog no. 11