Controls and Safety : Explosion-proof
  >  
Type 81
Type 81
Type 81
3 poles manual reset fail safe temperature limiters, double break contacts, calibration up to 130°C(266°F), 6.35 tabs, rating 25 A (3,3 A) à 250 V, 20 A (2,6 A) 400 V, rear mounting, to use when R290 highly flammable refrigerant classed A3 upon ISO 817 may be present. This is not Ex certified product but made specially for heat pumps applications
Controls and Safety
Explosion-proof
Check PDF
Click to see more languages available in the datasheet
Product applicable fields
    The product does not currently have its own area
product presentation

Main applications

Important Note: Fully compliant with the requirements for heat pumps and thermodynamic water heaters using R290 refrigerant, in accordance with EN 60335-2-40 (Special requirements for electric heat pumps) – Chapter on protection against arc flash and sparks.

General Description:

This thermal cut-out has been designed as a sealed device in accordance with IEC 60079-15:2017.
The thermal cut-out meets the requirements of Clause 9 of IEC 60079-15:2017.
The thermal cut-out has been examined and tested in accordance with Clause 26.5.1.2 of IEC 60079-0:2017 and Clause 11.2 of IEC 60079-15:2017.
The thermal cut-out has passed testing and complies with the relevant sections of IEC 60079-15:2017, as cited by IEC 60335-2-40:2024 and UL 60335-2-40:2022, applicable to equipment using Class A3 refrigerants.

Certification:

- UL: UL 60730-1, UL 60730-2-9, CAN/CSA E60730-1:15, UL/CSA E60730-2-9 (6000 cycles)
- CE: LVD certified by TÜV, EN60730-1, EN60730-2-9 (6.000 cycles)
- Explosive atmosphere: certified by TÜV according to standards and specific chapters above.

Certification test number: CL *********.

Technical features

Housing dimensions: see drawings

Capillary: Copper, capillary length 500 or 900 mm. Black PVC sleeve on capillary. Capillary minimum bending radius 5 mm.

For technical reasons, we do not recommend to use capillary length longer than 900 mm. We don’t recommend 500mm long capillary for calibration temperature above 90°C (194°F)

Special lengths on request.

Bulb: Copper, corkscrew type for temperatures from 70 to 130°C (158 to 266°F).

Straight uncoiled capillary available on request

Temperature sensing element: Liquid-filled thermostatic assembly whose boiling causes tripping of the contact.

Therefore, unlike liquid filled systems, these thermostats are sensitive to atmospheric pressure, and their reaction time is faster.

Terminals: Six 6.35 x 0.8, vertical quick connect terminals, epoxy sealed

Adjustment: Fixed setting

Mounting: rear bracket for 2 screws dia. 4mm, 60mm distance

Manual reset: Fail safe action, by waterproof front access button

Contacts: 3 poles single throw, 3 x 25A 250V, 3 x 20A 400V snap action, double break contacts.

Max ambient temperature on head: 85°C (185°F). Must not be higher of 10°C (18°F) than calibration temperature

Acceptable degree of pollution for use in 250V: 2

Acceptable degree of pollution for use in 400V: 2

Option: the spiral capillary in the shape of a bulb of dia. 6mm can be replaced by a tubular phial, but then the thermal response time is greatly increased.

Important safety note: Due to the presence of electrical connections near the reset button, disconnect the power supply before accessing it.